$0 Victoria Minimum Standards Checklist

Victoria Rental Kitchen, Bathroom, Laundry and Toilet Minimum Standards

Four Standards, Four Rooms, One Common Thread

Standards 3 through 6 in Schedule 4 of the Residential Tenancies Regulations 2021 cover the wet areas of a rental property — toilet, bathroom, kitchen, and laundry. Each standard has specific requirements that go beyond "the room exists and the fixtures work." Victorian landlords who treat these as a quick visual check during the pre-advertising walkthrough often miss the technical details that trigger non-compliance.

Standard 3: Toilet Facilities

The property must have at least one working toilet connected to a reticulated sewer, an EPA-approved wastewater system, or a council system. The toilet must be in a separate room — either standalone, inside the bathroom, or in a combined laundry/bathroom.

An outdoor toilet is only acceptable if a second indoor toilet also exists, or if the property is a pre-1991 Class 1a building. If neither exception applies, an outdoor-only toilet fails Standard 3.

Common failure: Properties in regional Victoria with aging septic systems that back up periodically. An intermittently functional toilet doesn't satisfy the standard. If the septic system needs pump-outs or repairs before the property can sustain reliable use, that work must be completed before advertising.

Standard 4: Bathroom Facilities

The bathroom must contain a washbasin and either a shower or a bath, both connected to a continuous hot and cold water supply. The shower head must meet a WELS 3-star water efficiency rating — upgrading to WELS 4-star for agreements starting from 1 March 2027.

A lower-rated shower head (1-star or 2-star) is only permitted where the property's age or plumbing configuration prevents a 3-star unit from being installed. This is a documented exception, not a blanket allowance for older properties.

Common failure: Shower heads with no WELS rating at all — typically older units installed before the rating system was widely adopted. If the shower head has no visible WELS label and you cannot verify its rating, replace it. A 3-star shower head costs under $30 at most hardware stores.

Free Download

Get the Victoria Minimum Standards Checklist

Everything in this article as a printable checklist — plus action plans and reference guides you can start using today.

Standard 5: Kitchen Facilities

The kitchen must have a dedicated space with three functional elements:

  1. A sink connected to hot and cold water
  2. A stovetop with at least two working burners
  3. A functional oven, if one was supplied with the property

The oven requirement is conditional. Standard 5 does not require an oven to be supplied; if one is provided, it must be functional. A dead element, broken thermostat, or door that will not close can mean the oven is not in good working order.

An exemption may apply if the property is listed on the Heritage Register at Heritage Council Victoria and has an approved exemption from the standard.

Common failure: Stovetops with one dead burner out of four. Even though three burners still work, the standard requires at least two — so a single-burner failure technically passes. But a stovetop where only one burner works fails.

Standard 6: Laundry Facilities

This standard only applies when the property provides on-site laundry facilities. There is no obligation to install a laundry if one doesn't exist.

Where a laundry is provided, it must be connected to functional hot and cold water supply. The taps must work, the drainage must function, and the connections must be operational.

Common failure: Older apartments where the "laundry" is a cupboard with capped-off water connections. If the connections are capped or disconnected, the laundry is not functional. Either restore the plumbing or remove the laundry designation from the listing and condition report.

What Happens When a Wet Area Standard Fails

A breach of any single minimum standard makes the entire property non-compliant under Section 65A. You cannot advertise it (Section 65B). A renter who signs an agreement for a non-compliant property can:

  • End the agreement without financial penalty before taking possession
  • Move in and request an urgent repair under Section 72
  • Apply to VCAT for a Rent Special Account order under Section 77 if the issue goes unresolved

Each offence carries a maximum penalty of 60 penalty units ($12,546 for individuals in 2026–27).

During the tenancy, any wet area failure that affects essential services — a broken hot water supply, a blocked toilet, a gas cooktop leak — qualifies as an urgent repair with the $2,500 tenant-initiated repair cap and VCAT's 2-business-day hearing guarantee.

Practical Audit Approach

Walk through each room with a checklist:

  • Toilet: Flush, confirm drainage, check the connection type
  • Bathroom: Run hot and cold taps at the basin and shower, check the shower head WELS rating, inspect for leaks under the basin
  • Kitchen: Run hot and cold water at the sink, test every stovetop burner, test the oven if one exists
  • Laundry (if provided): Run hot and cold taps, confirm drainage works, check for water damage around connections

Photograph each fixture in working condition. These photos become part of your compliance evidence under Section 65F.

The Victoria Rental Minimum Standards Compliance Guide includes a 15-category audit worksheet that walks through every room-by-room requirement, including the specific technical thresholds and common failure points that a visual-only inspection misses.

Get Your Free Victoria Minimum Standards Checklist

Download the Victoria Minimum Standards Checklist — a printable guide with checklists, scripts, and action plans you can start using today.